Straight coding, no invented defects
We code to the BS 7671 model. If something's C3, we call it C3, we don't upcode to sell you remediation.
Electrical Installation Condition Reports for homes, rentals and commercial premises. Fast fault finding when circuits trip or something isn't right, and honest remedial recommendations, not a shopping list.
NAPIT registered · legally compliant EICR · free surveys for remedial quotes
Straight explanation, no jargon padding, so you can decide whether it's the right call before you even ring us.
Most electrical fires don't announce themselves. A loose connection warms up over months, a bit of insulation crumbles behind a wall, an RCD sticks in place and stops tripping, none of it is visible until the smoke alarm goes off. A single EICR is what stands between a manageable finding and a claim your insurer refuses.
The same discipline we run on a single-socket call-out and a full commercial fit-out. Predictable, documented, tidy.
Free on-site survey. We look at the existing installation, the space and the outcome you need, no pressure, no obligation.
We scope the work, agree the spec in plain English and give you a fixed-price written quote with no hidden extras.
We turn up when we say we will, protect the space with dust sheets and keep disruption to your day to a minimum.
Every circuit is tested to BS 7671 (18th Edition). Nothing gets signed off until the readings are right.
You get NAPIT-backed certification, a tidy handover and a clear explanation of what's been done and why.
We code to the BS 7671 model. If something's C3, we call it C3, we don't upcode to sell you remediation.
Coded, dated, signed and produced to the standard format your council and insurer expect.
Clear call-out rate agreed before we come out; most single-fault jobs are diagnosed and fixed inside two hours.
If your EICR turns up C1 or C2 defects, we quote the remediation at a fixed price, you never see an open-ended day rate.
Tenancy changeover pressure? Ring us and we'll get you into the diary quickly.
Insulation resistance, earth loop impedance, RCD trip times, continuity, full dead and live testing, not a five-minute visual.
The specifics, so you can compare us like-for-like against anyone else you're quoting against.
Working across:
Chepstow · Newport · Bristol · Cardiff · Bath · Gloucestershire · Caldicot · Magor · Undy · South Wales · South West
The installation is isolated, the consumer unit is opened up, every circuit is disconnected in turn for dead testing (continuity, insulation resistance to at least 500V DC, polarity), then re-energised for live testing (earth fault loop impedance, prospective fault current, RCD trip times at ½ and 1× rated current). A representative sample of accessories is opened and inspected. All results go into the report along with any coded defects, and you get a certificate stating whether the installation is satisfactory or unsatisfactory.
C1, danger present, action required immediately. C2, potentially dangerous, remedial action required. C3, improvement recommended, not required for the report to pass. FI, further investigation required without delay. A report is 'unsatisfactory' if there's a C1, C2 or FI code. Understanding the coding matters: we walk you through every finding rather than handing you the paperwork and vanishing.
A tripping RCD, a dead ring final, a socket that's arcing, a light that flickers under load, each has a diagnostic pathway. We start with insulation resistance testing to narrow the fault to a circuit, then use continuity and voltage-drop testing to localise it further, then physically inspect the suspect section. Most single faults are found and fixed inside two hours; harder ones sometimes need a follow-up visit but we quote that up front.
Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, private landlords must have an EICR carried out at least every 5 years, provide a copy to tenants within 28 days, and produce it to the local authority within 7 days if requested. Welsh Government has published similar guidance. We produce reports formatted to satisfy councils across the areas we cover.
Domestic EICRs typically cover 8–14 circuits on a single-phase supply and take around half a day. Commercial EICRs may involve three-phase distribution, dozens of circuits across multiple boards, and require careful planning around trading hours. We often carry these out in phases so parts of the site stay operational. Both are quoted transparently before we start.
Still unsure? Ring us on 07491 966787 , surveys and quotes are free.
EICR pricing depends on the number of circuits and the complexity of the installation, so we quote per property. Ring us with the property type and rough age and we'll give you a straight ballpark before we come out. Surveys and remedial quotes are always free.
A typical three-bedroom domestic EICR is around half a day. Larger properties and commercial premises take longer, we'll give you a time estimate at booking. Power is off in sections during dead testing, so plan the day accordingly.
For privately rented properties in England (and increasingly Wales), yes, at every change of tenancy and at least every 5 years. For owner-occupied properties it's recommended every 10 years, and often required by insurers or during a house sale.
An 'unsatisfactory' report means at least one C1, C2 or FI code. We give you a fixed-price quote to remediate exactly what's coded, not a padded list. Once the work is done we re-test the affected circuits and issue a Minor Works or Electrical Installation Certificate.
Most single-fault call-outs are diagnosed and fixed inside two hours. Call-out rates are agreed before we come out, with separate standard-hours and out-of-hours cover.
PAT (portable appliance testing) is a separate discipline from fixed-wiring EICRs. If you specifically need PAT testing across an office of computers, ring us to discuss, for most requests, what people actually need is a fixed-wiring EICR.
For commercial premises where testing during trading hours isn't practical, yes, we schedule EICRs evenings and weekends. Rates reflect the out-of-hours booking and are agreed in the written quote.
Where a defect is quick, safe and clearly within scope, retightening a terminal, replacing a broken faceplate, we handle it on the day and note it in the report. Anything bigger is quoted separately so you get a clean coded record.
Yes. H&H Electrical is NAPIT registered, our EV work is NAPIT-accredited and Ohme approved, and we carry public liability, employers' liability and indemnity insurance in full.
We cover Chepstow, Newport, Bristol & across South Wales, the South West, Cardiff, Bath, Gloucestershire, Caldicot, Magor and Undy. Ring us if you're just outside, most of the time we can still help.
Bank transfer or cash. We don't take card. Small jobs are call-out plus materials; larger jobs are quoted at a fixed price up front so you know the total before we start.
Replace outdated fuse boards with modern 18th Edition consumer units. RCBO protection on every circuit for a safer, code-compliant installation.
Learn more Fixed-price quotesWhole-house and property rewires with minimal disruption. Modern circuits, safe cabling and a clean finish, quoted up front, no surprises.
Learn more Out-of-hoursLost power, tripped circuits, dangerous faults, call us any time for a rapid response, out-of-hours emergency cover included.
Learn moreFree survey. Fixed-price written quote. Work booked in around you, usually the same week.
Free survey · fixed-price written quote · payment by bank transfer or cash